材质:ABS
特点:测试高斯,让你远离辐射,对你的健康有好处
特殊功能5-led指标,分别代表不同的辐射值;使用方便;1 x 9V(包括供电)
应用50 / 60Hz频率监测
深绿色0 1.5毫高斯;绿光1.5至2.5毫高斯;黄2.5至10毫高斯;橙10至20毫高斯;红20 +毫高斯;
尺寸:14.3厘米×2.9厘米×5.3厘米
重量:101克
装箱单
1x主机
1×电池
1×英文用户手册
Aokin KII K2 K-II Electromagnetic Field EMF Gauss Meter Deluxe EMF GHOST HUNTING METER detector
K 2 KII K-II K2 EMF Meter
The KII EMF Meter is a hand held meter brought out by KII Enterprises. It has a press down button to activate it and it requires this to be held down to monitor readings. This modification adds a switch to the circuit which produces the same effect as if the button was held down.
Other possible modifications would be to add an output jack and digital meter to the KII - this is looked at in the Trifield Natural EM Meter Modification and specifics given in the tech bench board on the GRI Forum.
K-II output being logged along with Magnetic Field, Temperature and light intensity.
First a little background on the KII meter. It has 5 lights which indicate the level of EMF:
Green - Always on indicating battery OK and a "normal" level of 0 to 1.5 milliGauss
Green - "Low" 1.5 to 2.5 milliGauss
Yellow - "Caution" 2.5 to 10 milliGauss
Orange - "High" 10 to 20 milliGauss
Red - "Warning" 20+ milliGauss
Frequencies detected are 50/60Hz (50-1000Hz - ELF) (1000-20,000Hz - VLF), Accuracy 5% (typical).
The KII differs from many other low cost meters in that it not only measures the Electro Magnetic Field in the Extremely Low Frequency (ELF) range, but also the Very Low Frequency (VLF) range. The ELF range which is generally termed to be between 3-3,000Hz borders on DC as well as AC.
Higher priced meters such as the The Tri-Field Natural EM meter are designed to be able to operate exclusively in the natural DC range which is from 0-3Hz (Sub Extremely Low Frequency - SELF) and includes the frequencies of humans and the earth itself.
OPERATION OF THE K-II
When the meter is initially turned on it gives a full scale reading and then a half scale to indicate it's powered up. It then returns a normal reading with one green LED illuminated - indicating 0-1.5mG. Any disturbance will now be indicated by the meter. If the finger is lifted the single LED will extinguish indicating the unit is off.
The benefit of the modification is obvious and rules out the possibility of human intervention (accidental or otherwise) with the meter's original momentary switch. Such intervention can be noticed by the first light (green) going out before a "spike" occurs - this single light should always be on indicating the unit is powered up.
The following pics display the modification and the finished switch in place. The modification is fairly self explanatory and note that the original switch still works as previous. Test the switch and connection points before soldering into place and ensure nothing is touching other components on reassembly. As with any such modification it will likely void any warranty and care should be taken to ensure correct connections are made and no damage is done to other components - basically it's purely at your own risk. We have modified our K-II (pictured) and it works great, but cannot warrant attempts at the same will be successful.
This modification is provided with the intention of allowing all groups to improve the quality of results obtained with the K-II Meter. We do ask that if you do find this useful please provide a link back to this page and allow others the same opportunity. Further information/discussion may be found in the Tech Bench board of the GRI EMF k-ii便携式5-led指标的高斯计